VFVerifiedFilters

Parker

Parker R890H0825A

Industrial filter element

OEM ManufacturerAbsolute Rated
Representative illustration, not the actual part

Parker R890H0825A specifications

The Parker R890H0825A is a 20µm microglass filter element. Filtration efficiency is rated at β20(c) ≥ 200 per ISO 16889. Seals are VITON. Operating temperature: -13°F to 250°F. Collapse pressure rating is 365 PSID.

Physical fit

Outer Diameter (O.D.)
Not yet verified from an OEM source
Inner Diameter (I.D.)
Not yet verified from an OEM source
Overall Length
Not yet verified from an OEM source
Micron Rating
20µmSource under review
Seal Material
VITONSource under review
Connection / Thread
Not yet verified from an OEM source

Performance: Parker published values

These are Parker's own published numbers. Performance specs differ by brand and are never inherited across cross-references.

Beta Ratio (ISO 16889)
β20(c) ≥ 200Source under review
Media Type
MICROGLASS
Collapse Rating
365 PSIDSource under review
Flow Direction
OUTSIDE-INSource under review
Operating Temperature
-13°F to 250°FSource under review

Application & Compatibility

The PARKER R890H0825A is designed for use in hydraulic and lubrication filtration systems. With a 20µm rating, this element is suitable for pump and component protection in industrial hydraulic circuits. VITON seals provide compatibility with petroleum-based fluids, synthetic fluids, phosphate esters, and water-glycol mixtures.

The 365 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.

Frequently Asked Questions

What micron rating is the Parker R890H0825A?

The Parker R890H0825A has a 20µm micron rating with microglass filter media, rated at β20(c) ≥ 200 per ISO 16889.

What seal material does the Parker R890H0825A use?

The Parker R890H0825A uses VITON seals.

What is the collapse pressure rating of the Parker R890H0825A?

The Parker R890H0825A has a collapse pressure rating of 365 PSID. This indicates the maximum differential pressure the element can withstand without structural failure.

What is the operating temperature range for the Parker R890H0825A?

The Parker R890H0825A is rated for -13°F to 250°F.

How this entry is verified

Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.

Our verification standards →

Request a quote for the Parker R890H0825A

Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.

Add your number and we'll call you back within the hour with pricing.

Labeled Cross-References

Every cross-reference on file carries its evidence status: verified, sourced, or transitive

Fast Response

Quotes and answers within 24 hours

Expert Support

Real filtration specialists, not call centers