VFVerifiedFilters

Parker

Parker PR3324

Industrial filter element

Verified SourceAbsolute Rated
Representative illustration, not the actual part

Parker PR3324 specifications

The Parker PR3324 is a 3µm microglass filter element. Filtration efficiency is rated at β200 ≥ 3 per ISO 16889. Seals are VITON, rated for -13°F to 250°F. Collapse pressure rating is 305 PSID. 3 verified cross-references are available from aftermarket manufacturers.

Physical fit

Outer Diameter (O.D.)
Not yet verified from an OEM source
Inner Diameter (I.D.)
Not yet verified from an OEM source
Overall Length
Not yet verified from an OEM source
Micron Rating
3µmSource under review
Seal Material
VITONSource under review
Connection / Thread
Not yet verified from an OEM source

Performance: Parker published values

These are Parker's own published numbers. Performance specs differ by brand and are never inherited across cross-references.

Efficiency (ISO 16889)
β200 ≥ 3
Media Type
MICROGLASS
Collapse Rating
305 PSID
Flow Direction
OUTSIDE-IN
Operating Temperature
-13°F to 250°F

What replaces the Parker PR3324?

3 published cross-references on file. Select to expand.

A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.

Published cross-references

Part NumberManufacturerMatch
HP66RNL14-3MVHy-ProVerified
SF660RN-13-03UMVSwift FiltersSourced
05-0376FilterMartSourced
Get a quote on any of these →

Application & Compatibility

The PARKER PR3324 is designed for use in hydraulic and lubrication filtration systems. With a 3µm rating, this element is suitable for servo valve protection and high-precision hydraulic systems. VITON seals provide compatibility with petroleum-based fluids, synthetic fluids, phosphate esters, and water-glycol mixtures.

The 305 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.

Frequently Asked Questions

What micron rating is the Parker PR3324?

The Parker PR3324 has a 3µm micron rating with microglass filter media, rated at β200 ≥ 3 per ISO 16889.

What seal material does the Parker PR3324 use?

The Parker PR3324 uses VITON seals, rated for -13°F to 250°F.

Is there a cross-reference for the Parker PR3324?

Yes. There are 3 verified cross-references for the Parker PR3324 from manufacturers including Hy-Pro, Swift Filters, FilterMart. Contact VerifiedFilters for specific part numbers and availability.

What is the collapse pressure rating of the Parker PR3324?

The Parker PR3324 has a collapse pressure rating of 305 PSID. This indicates the maximum differential pressure the element can withstand without structural failure.

What is the operating temperature range for the Parker PR3324?

The Parker PR3324 is rated for -13°F to 250°F, determined by its VITON seals.

How this entry is verified

Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.

Our verification standards →

Request a quote for the Parker PR3324

Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.

Add your number and we'll call you back within the hour with pricing.

Verified Cross-References

520,000+ verified cross-references on file

Fast Response

Quotes and answers within 24 hours

Expert Support

Real filtration specialists, not call centers