Parker
Parker G01347
Industrial filter element
Parker G01347 specifications
The Parker G01347 is a 10µm microglass filter element. Filtration efficiency is rated at β200 ≥ 13 per ISO 16889. Seals are BUNA, rated for -13°F to 250°F. Collapse pressure rating is 150 PSID. 2 verified cross-references are available from aftermarket manufacturers.
Physical fit
- Outer Diameter (O.D.)
- Not yet verified from an OEM source
- Inner Diameter (I.D.)
- Not yet verified from an OEM source
- Overall Length
- Not yet verified from an OEM source
- Micron Rating
- 10µmSource under review
- Seal Material
- BUNASource under review
- Connection / Thread
- Not yet verified from an OEM source
Performance: Parker published values
These are Parker's own published numbers. Performance specs differ by brand and are never inherited across cross-references.
- Efficiency (ISO 16889)
- β200 ≥ 13
- Media Type
- MICROGLASS
- Collapse Rating
- 150 PSID
- Flow Direction
- INSIDE-OUT
- Operating Temperature
- -13°F to 250°F
What replaces the Parker G01347?
2 published cross-references on file. Select to expand.
What replaces the Parker G01347?
2 published cross-references on file. Select to expand.
A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.
Published cross-references
| Part Number | Manufacturer | Match |
|---|---|---|
| HPQ280374L9-10MB | — | Verified |
| 25-0680 | FilterMart | Sourced |
Application & Compatibility
The PARKER G01347 is designed for use in hydraulic and lubrication filtration systems. With a 10µm rating, this element is suitable for proportional valve protection and general hydraulic systems. BUNA seals provide compatibility with standard petroleum-based fluids and mineral oils.
The 150 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.
Frequently Asked Questions
What micron rating is the Parker G01347?
What seal material does the Parker G01347 use?
Is there a cross-reference for the Parker G01347?
What is the collapse pressure rating of the Parker G01347?
What is the operating temperature range for the Parker G01347?
How this entry is verified
Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.
Request a quote for the Parker G01347
Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.
Verified Cross-References
520,000+ verified cross-references on file
Fast Response
Quotes and answers within 24 hours
Expert Support
Real filtration specialists, not call centers