Parker
Parker 931018Q
50P series filter element
Parker 931018Q specifications
The Parker 931018Q is a 20µm microglass filter element. It measures 3.85" OD x 1.61" ID x 9.25" long. Filtration efficiency is rated at β200 ≥ 20 per ISO 16889. Seals are Viton/FKM, rated for -15°F to 275°F. Collapse pressure rating is 150 PSID. 3 verified cross-references are available from aftermarket manufacturers. Specifications verified. Last reviewed: February 2026
Physical fit
- Outer Diameter (O.D.)
- 3.85"OEM-published
- Inner Diameter (I.D.)
- 1.61"OEM-published
- Overall Length
- 9.25"OEM-published
- Micron Rating
- 20µmOEM-published
- Seal Material
- Viton/FKMOEM-published
- Connection / Thread
- Not yet verified from an OEM source
Performance: Parker published values
These are Parker's own published numbers. Performance specs differ by brand and are never inherited across cross-references.
- Efficiency (ISO 16889)
- β200 ≥ 20
- Media Type
- Microglass
- Collapse Rating
- 150 PSID
- Flow Direction
- OUTSIDE-IN
- Max Operating Pressure
- 5000 PSI
- Operating Temperature
- -15°F to 275°F
- Series
- 50P
About the Parker 931018Q
Parker 931018Q -- Replacement hydraulic filter element, 20um, Microglass, Viton (FKM) seals, for 50P-1/50PR -1
What replaces the Parker 931018Q?
3 published cross-references on file. Select to expand.
What replaces the Parker 931018Q?
3 published cross-references on file. Select to expand.
A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.
Published cross-references
| Part Number | Manufacturer | Match |
|---|---|---|
| HPKL9-25MV | Hy-Pro | Verified |
| SF9700-9-25UM | Swift Filters | Sourced |
| SF9700-9-25UMV | Swift Filters | Sourced |
Application & Compatibility
The PARKER 931018Q is designed for use in hydraulic and lubrication filtration systems. With a 20µm rating, this element is suitable for pump and component protection in industrial hydraulic circuits. Viton/FKM seals provide compatibility with petroleum-based fluids, synthetic fluids, phosphate esters, and water-glycol mixtures.
The 150 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.
Frequently Asked Questions
What micron rating is the Parker 931018Q?
What are the dimensions of the Parker 931018Q?
What seal material does the Parker 931018Q use?
Is there a cross-reference for the Parker 931018Q?
What is the collapse pressure rating of the Parker 931018Q?
What is the operating temperature range for the Parker 931018Q?
How this entry is verified
Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.
Request a quote for the Parker 931018Q
Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.
Verified Cross-References
520,000+ verified cross-references on file
Fast Response
Quotes and answers within 24 hours
Expert Support
Real filtration specialists, not call centers