Hy-Pro
Hy-Pro HPTX3L11-25MB
Industrial filter element

Hy-Pro HPTX3L11-25MB specifications
The Hy-Pro HPTX3L11-25MB is a 25µm nominal (β-rated, absolute 22µm) dualglass filter element. Filtration efficiency is rated at β4000 per ISO 16889. Seals are Nitrile (Buna-N), rated for -45°F to 225°F. 21 verified cross-references are available from aftermarket manufacturers.
Physical fit
- Outer Diameter (O.D.)
- Not yet verified from an OEM source
- Inner Diameter (I.D.)
- Not yet verified from an OEM source
- Overall Length
- Not yet verified from an OEM source
- Micron Rating
- 25µm nominal (β-rated, absolute 22µm)Inherited from cross-reference
- Seal Material
- Nitrile (Buna-N)Inherited from cross-reference
- Connection / Thread
- Not yet verified from an OEM source
Performance: Hy-Pro published values
These are Hy-Pro's own published numbers. Performance specs differ by brand and are never inherited across cross-references.
- Efficiency (ISO 16889)
- β4000
- Efficiency
- 99.97%
- Media Type
- DualglassG8 High-performance glass fiber media
- Operating Temperature
- -45°F to 225°F
About the Hy-Pro HPTX3L11-25MB
Hy-Pro HPTX3L11-25MB is a filter element rated at 22 µm (25 µm nominal), a beta ratio of β ≥ 4000, and measuring 4.96 in OD and 0.41 in ID. It uses Dualglass media and Nitrile (Buna-N) seals, rated for -45 °F to 225 °F (Donaldson Hy-Pro HP101 Data Sheet FE-101-071724, p.4).
What replaces the Hy-Pro HPTX3L11-25MB?
21 published cross-references on file. Select to expand.
What replaces the Hy-Pro HPTX3L11-25MB?
21 published cross-references on file. Select to expand.
A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.
Published cross-references
| Part Number | Manufacturer | Match |
|---|---|---|
| SFTXW3-11-25UM | Swift Filters | Sourced |
| TXX8A-10 | Fairey Arlon | Verified |
| TXX8A-10-B | Fairey Arlon | Verified |
| MR6302A25A | MP Filtri | Verified |
| VR171B2C20 | Vickers | Verified |
| P172465 | Donaldson | Verified |
| FT6302A25A | MP Filtri | Verified |
| DER171B2C20 | Denison | Verified |
| FC1097F025B | Finn | Verified |
| TXW8A-CC25-B | Fairey Arlon | Verified |
| TXW8A-20 | Fairey Arlon | Verified |
| TXW8A-GDL20-B | Fairey Arlon | Verified |
| TXW8A-CC25 | Fairey Arlon | Verified |
| TXW8A-20-B | Fairey Arlon | Verified |
| TXW8A-GDL20 | Fairey Arlon | Verified |
| FC1097Q025B | Finn | Verified |
| 3i2140 | Caterpillar | Verified |
| CRS390.3 | Donaldson | Verified |
| P173055 | Donaldson | Verified |
| FT6302P25A | Vickers | Verified |
| AFPOVL4225 | Airfil | Verified |
Application & Compatibility
The HY-PRO HPTX3L11-25MB is designed for use in hydraulic and lubrication filtration systems. With a 25µm nominal (β-rated, absolute 22µm) rating, this element is suitable for pump and component protection in industrial hydraulic circuits. Nitrile (Buna-N) seals provide compatibility with standard petroleum-based fluids and mineral oils.
Frequently Asked Questions
What micron rating is the Hy-Pro HPTX3L11-25MB?
What seal material does the Hy-Pro HPTX3L11-25MB use?
Is there a cross-reference for the Hy-Pro HPTX3L11-25MB?
What is the operating temperature range for the Hy-Pro HPTX3L11-25MB?
How this entry is verified
Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.
Request a quote for the Hy-Pro HPTX3L11-25MB
Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.
Verified Cross-References
520,000+ verified cross-references on file
Fast Response
Quotes and answers within 24 hours
Expert Support
Real filtration specialists, not call centers