VFVerifiedFilters

Hy-Pro

Hy-Pro HPKTL9-25WB

HPKTL series filter element

Verified SourceAbsolute Rated
Representative illustration, not the actual part

Hy-Pro HPKTL9-25WB specifications

The Hy-Pro HPKTL9-25WB is a 25µm ss wire mesh filter element. Filtration efficiency is rated at β200 per ISO 16889. Seals are Nitrile (Buna-N), rated for -45°F to 225°F. Collapse pressure rating is 150 PSID. 1 verified cross-reference is available from aftermarket manufacturers.

Physical fit

Outer Diameter (O.D.)
Not yet verified from an OEM source
Inner Diameter (I.D.)
Not yet verified from an OEM source
Overall Length
Not yet verified from an OEM source
Micron Rating
25µmSource under review
Seal Material
Nitrile (Buna-N)Source under review
Connection / Thread
Not yet verified from an OEM source

Performance: Hy-Pro published values

These are Hy-Pro's own published numbers. Performance specs differ by brand and are never inherited across cross-references.

Efficiency (ISO 16889)
β200
Media Type
SS Wire MeshStainless steel wire mesh
Collapse Rating
150 PSID
Max Operating Pressure
100 psi (6.9 bar)
Operating Temperature
-45°F to 225°F
Series
HPKTL

Additional

Filter Type
In-Tank Element
Element Length
9" (229 mm)
Beta Ratio
Nominal
Max Temperature
225°F (107°C)

About the Hy-Pro HPKTL9-25WB

Hy-Pro HPKTL9-25WB hydraulic filter element. Corrosion resistant steel end caps and center tube. Nitrile seals (-45°F to 225°F).

What replaces the Hy-Pro HPKTL9-25WB?

1 published cross-reference on file. Select to expand.

A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.

Published cross-references

Part NumberManufacturerMatch
HKS25WHydacVerified
Get a quote on any of these →

Application & Compatibility

The HY-PRO HPKTL9-25WB is designed for use in hydraulic and lubrication filtration systems. With a 25µm rating, this element is suitable for pump and component protection in industrial hydraulic circuits. Nitrile (Buna-N) seals provide compatibility with standard petroleum-based fluids and mineral oils.

The 150 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.

Frequently Asked Questions

What micron rating is the Hy-Pro HPKTL9-25WB?

The Hy-Pro HPKTL9-25WB has a 25µm micron rating with ss wire mesh filter media, rated at β200 per ISO 16889.

What seal material does the Hy-Pro HPKTL9-25WB use?

The Hy-Pro HPKTL9-25WB uses Nitrile (Buna-N) seals, rated for -45°F to 225°F.

Is there a cross-reference for the Hy-Pro HPKTL9-25WB?

Yes. There is 1 verified cross-reference for the Hy-Pro HPKTL9-25WB from manufacturers including Hydac. Contact VerifiedFilters for specific part numbers and availability.

What is the collapse pressure rating of the Hy-Pro HPKTL9-25WB?

The Hy-Pro HPKTL9-25WB has a collapse pressure rating of 150 PSID. This indicates the maximum differential pressure the element can withstand without structural failure.

What is the operating temperature range for the Hy-Pro HPKTL9-25WB?

The Hy-Pro HPKTL9-25WB is rated for -45°F to 225°F, determined by its Nitrile (Buna-N) seals.

How this entry is verified

Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.

Our verification standards →

Request a quote for the Hy-Pro HPKTL9-25WB

Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.

Add your number and we'll call you back within the hour with pricing.

Verified Cross-References

520,000+ verified cross-references on file

Fast Response

Quotes and answers within 24 hours

Expert Support

Real filtration specialists, not call centers