Hy-Pro HP60L4-1MV

HP60L series filter element

Verified SourceAbsolute Rated
OD 3.1"L 4.648"ID 1.724"
Dimensional schematic from verified specifications

Hy-Pro HP60L4-1MV specifications

The Hy-Pro HP60L4-1MV is a 1µm nominal (β-rated, absolute 3µm) dualglass filter element. It measures 3.1" OD x 1.724" ID x 4.648" long. Filtration efficiency is rated at β4000 per ISO 16889. Seals are Fluorocarbon (Viton), rated for -20°F to 250°F. Collapse pressure rating is 290 PSID. 20 verified cross-references are available from aftermarket manufacturers. Specifications verified. Last reviewed: May 2026

Physical fit

Outer Diameter (O.D.)
3.1"OEM-published
Inner Diameter (I.D.)
1.724"OEM-published
Overall Length
4.648"OEM-published
Micron Rating
1µm nominal (β-rated, absolute 3µm)OEM-published
Seal Material
Fluorocarbon (Viton)OEM-published
Connection / Thread
Not yet verified from an OEM source

Performance: Hy-Pro published values

These are Hy-Pro's own published numbers. Performance specs differ by brand and are never inherited across cross-references.

Efficiency (ISO 16889)
β4000
Efficiency
99.97%
Media Type
DualglassG8 High-performance glass fiber media
Collapse Rating
290 PSID
Max Operating Pressure
1200 psi (83 bar)
Operating Temperature
-20°F to 250°F
Series
HP60L

Additional

Filter Type
Cartridge Element
Element Length
4" (102 mm)
Beta Ratio
β3[C] ≥ 4000
Max Temperature
225°F (107°C)

About the Hy-Pro HP60L4-1MV

Hy-Pro HP60L4-1MV is a filter element rated at 3 µm (1 µm nominal), a beta ratio of β ≥ 4000, 290 psid collapse pressure, and measuring 3.1 in OD, 1.724 in ID, and 4.65 in length. It uses Dualglass media and Fluorocarbon (Viton) seals, rated for -20 °F to 250 °F (Hy-Pro datasheet).

What replaces the Hy-Pro HP60L4-1MV?

20 published cross-references on file. Select to expand.

A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.

Published cross-references

Part NumberManufacturerMatch
SF9600-4-1UMVSwift FiltersSourced
HC9600FDZ4ZPallVerified
HC9600FKZ4ZPallVerified
HC9600FUZ4ZPallVerified
2960L01V04Separation TechnologiesVerified
3960GGBV04Separation TechnologiesVerified
HC9600FMZ4ZPallVerified
9600L012F1PurolatorVerified
H9604MAAVLFiltersoftVerified
H9604MAAVFiltersoftVerified
M69604MAAVLFiltersoftVerified
M69604MAAVFiltersoftVerified
A912402KaydonVerified
KMP9600A01V04KaydonVerified
3830-16-025-CHilcoVerified
P566204DonaldsonVerified
DT-9600-4-2UMDonaldsonVerified
HC9600FCZ4ZPallVerified
HC9600FRZ4ZPallVerified
HC9600FHZ4ZPallVerified
Get a quote on any of these →

Application & Compatibility

The HY-PRO HP60L4-1MV is designed for use in hydraulic and lubrication filtration systems. With a 1µm nominal (β-rated, absolute 3µm) rating, this element is suitable for proportional valve protection and general hydraulic systems. Fluorocarbon (Viton) seals provide compatibility with petroleum-based fluids, synthetic fluids, phosphate esters, and water-glycol mixtures.

The 290 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.

Frequently Asked Questions

What micron rating is the Hy-Pro HP60L4-1MV?

The Hy-Pro HP60L4-1MV has a 1µm nominal (β-rated, absolute 3µm) micron rating with dualglass filter media, rated at β4000 per ISO 16889.

What are the dimensions of the Hy-Pro HP60L4-1MV?

The Hy-Pro HP60L4-1MV measures 3.1" OD, 1.724" ID, 4.648" overall length.

What seal material does the Hy-Pro HP60L4-1MV use?

The Hy-Pro HP60L4-1MV uses Fluorocarbon (Viton) seals, rated for -20°F to 250°F.

Is there a cross-reference for the Hy-Pro HP60L4-1MV?

Yes. There are 20 verified cross-references for the Hy-Pro HP60L4-1MV from manufacturers including Swift Filters, Pall, Separation Technologies, Purolator. Contact VerifiedFilters for specific part numbers and availability.

What is the collapse pressure rating of the Hy-Pro HP60L4-1MV?

The Hy-Pro HP60L4-1MV has a collapse pressure rating of 290 PSID. This indicates the maximum differential pressure the element can withstand without structural failure.

What is the operating temperature range for the Hy-Pro HP60L4-1MV?

The Hy-Pro HP60L4-1MV is rated for -20°F to 250°F, determined by its Fluorocarbon (Viton) seals.

How this entry is verified

Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.

Our verification standards →

Request a quote for the Hy-Pro HP60L4-1MV

Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.

Add your number and we'll call you back within the hour with pricing.

Verified Cross-References

520,000+ verified cross-references on file

Fast Response

Quotes and answers within 24 hours

Expert Support

Real filtration specialists, not call centers