Hy-Pro
Hy-Pro HP20SL4-6AV
- Micron
- 6µm
- Media
- Dualglass + Water Removal
- O.D.
- 1.75"
- I.D.
- 1.021"
- Length
- 4.6"
- Seal
- Fluorocarbon (Viton)
- Efficiency
- β4000
- Collapse
- 290 PSID
Hy-Pro HP20SL4-6AV is a filter element rated at 6 µm (6 µm nominal), a beta ratio of β ≥ 4000, 290 psid collapse pressure, and measuring 1.75 in OD, 1.021 in ID, and 4.6 in length. It uses Dualglass + Water Removal media and Fluorocarbon (Viton) seals, rated for -20 °F to 250 °F (Donaldson Hy-Pro HP101 Data Sheet FE-101-071724, p.4).
Request a quote
Pricing and availability within 24 hours.
Get a quote →Or call (385) 202-5628Mon–Fri, 8am–5pm MT
- Part Number
- HP20SL4-6AV
- Manufacturer
- Hy-Pro
Hy-Pro HP20SL4-6AV specifications
The Hy-Pro HP20SL4-6AV is a 6µm dualglass + water removal filter element. It measures 1.75" OD x 1.021" ID x 4.6" long. Filtration efficiency is rated at β4000 per ISO 16889. Seals are Fluorocarbon (Viton), rated for -20°F to 250°F. Collapse pressure rating is 290 PSID. Specifications verified. Last reviewed: May 2026
Performance
- Series
- HP20SL
- Media Type
- Dualglass + Water RemovalG8 glass fiber with water removal scrim
- Micron Rating
- 6µm
- Max Operating Pressure
- 4000 psi (275 bar)
- Collapse Rating
- 290 PSID
- Efficiency (ISO 16889)
- β4000
- Efficiency
- 99.97%
- Operating Temperature
- -20°F to 250°F
Dimensions
- Seal Material
- Fluorocarbon (Viton)
- O.D. (inches)
- 1.75"
- I.D. (inches)
- 1.021"
- O.A.L. (inches)
- 4.6"
Additional
- Filter Type
- Cartridge Element
- Element Length
- 4" (102 mm)
- Beta Ratio
- β7[C] ≥ 4000
- Max Temperature
- 225°F (107°C)
Application & Compatibility
The HY-PRO HP20SL4-6AV is designed for use in hydraulic and lubrication filtration systems. With a 6µm rating, this element is suitable for proportional valve protection and general hydraulic systems. Fluorocarbon (Viton) seals provide compatibility with petroleum-based fluids, synthetic fluids, phosphate esters, and water-glycol mixtures.
The 290 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.
Frequently Asked Questions
What micron rating is the Hy-Pro HP20SL4-6AV?
What are the dimensions of the Hy-Pro HP20SL4-6AV?
What seal material does the Hy-Pro HP20SL4-6AV use?
What is the collapse pressure rating of the Hy-Pro HP20SL4-6AV?
What is the operating temperature range for the Hy-Pro HP20SL4-6AV?
Request a quote for the Hy-Pro HP20SL4-6AV
Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.
Verified Cross-References
520,000+ verified cross-references on file
Fast Response
Quotes and answers within 24 hours
Expert Support
Real filtration specialists, not call centers