VFVerifiedFilters

EPE

EPE 1.0013H10SL-A00-0-N

Industrial filter element

Verified SourceAbsolute Rated
OD 2.36"L 10"ID 1.39"
Dimensional schematic from verified specifications

EPE 1.0013H10SL-A00-0-N specifications

The EPE 1.0013H10SL-A00-0-N is a 10µm fiberglass hp filter element. It measures 2.36" OD x 1.39" ID x 10" long. Filtration efficiency is rated at β1000 per ISO 16889. Seals are Nitrile (Buna-N), rated for -13°F to 250°F. Collapse pressure rating is 425 PSID. 1 verified cross-reference is available from aftermarket manufacturers. Specifications verified. Last reviewed: April 2026

Physical fit

Outer Diameter (O.D.)
2.36"Verified via cross-reference
Inner Diameter (I.D.)
1.39"Verified via cross-reference
Overall Length
10"Verified via cross-reference
Micron Rating
10µmVerified via cross-reference
Seal Material
Nitrile (Buna-N)Verified via cross-reference
Connection / Thread
Not yet verified from an OEM source

Performance: EPE published values

These are EPE's own published numbers. Performance specs differ by brand and are never inherited across cross-references.

Efficiency (ISO 16889)
β1000
Media Type
Fiberglass HP
Collapse Rating
425 PSID
Operating Temperature
-13°F to 250°F

What replaces the EPE 1.0013H10SL-A00-0-N?

1 published cross-reference on file. Select to expand.

A cross-reference confirms dimensional fit and micron rating, not performance equivalence. Beta ratio, collapse rating, media, and service life can differ between brands.

Published cross-references

Part NumberManufacturerMatch
HP44L10-10MNHy-ProVerified
Get a quote on any of these →

Application & Compatibility

The EPE 1.0013H10SL-A00-0-N is designed for use in hydraulic and lubrication filtration systems. With a 10µm rating, this element is suitable for proportional valve protection and general hydraulic systems. Nitrile (Buna-N) seals provide compatibility with standard petroleum-based fluids and mineral oils.

The 425 PSID collapse rating indicates the maximum differential pressure this element can withstand during cold starts or bypass conditions without structural failure. Ensure your system's maximum differential pressure does not exceed this rating.

Frequently Asked Questions

What micron rating is the EPE 1.0013H10SL-A00-0-N?

The EPE 1.0013H10SL-A00-0-N has a 10µm micron rating with fiberglass hp filter media, rated at β1000 per ISO 16889.

What are the dimensions of the EPE 1.0013H10SL-A00-0-N?

The EPE 1.0013H10SL-A00-0-N measures 2.36" OD, 1.39" ID, 10" overall length.

What seal material does the EPE 1.0013H10SL-A00-0-N use?

The EPE 1.0013H10SL-A00-0-N uses Nitrile (Buna-N) seals, rated for -13°F to 250°F.

Is there a cross-reference for the EPE 1.0013H10SL-A00-0-N?

Yes. There is 1 verified cross-reference for the EPE 1.0013H10SL-A00-0-N from manufacturers including Hy-Pro. Contact VerifiedFilters for specific part numbers and availability.

What is the collapse pressure rating of the EPE 1.0013H10SL-A00-0-N?

The EPE 1.0013H10SL-A00-0-N has a collapse pressure rating of 425 PSID. This indicates the maximum differential pressure the element can withstand without structural failure.

What is the operating temperature range for the EPE 1.0013H10SL-A00-0-N?

The EPE 1.0013H10SL-A00-0-N is rated for -13°F to 250°F, determined by its Nitrile (Buna-N) seals.

How this entry is verified

Every specification on this page names its source: manufacturer documents first, distributor catalogs second, decoded part-number patterns labeled as such. When a value has not been verified from an OEM source, the cell says so. Cross-references are fit claims, never performance claims.

Our verification standards →

Request a quote for the EPE 1.0013H10SL-A00-0-N

Tell us where to send it and we'll get you pricing and availability within 24 hours. Leave a number and we'll call you back within the hour.

Add your number and we'll call you back within the hour with pricing.

Verified Cross-References

520,000+ verified cross-references on file

Fast Response

Quotes and answers within 24 hours

Expert Support

Real filtration specialists, not call centers