PR2857 vs HP501L5-3M
Source: hypro cross-referenceVerified
Manufacturer
Parker
Hy-Pro
Outer Diameter (in)
3.32
3.321
Inner Diameter (in)
1.88
1.86
Length (in)
5.6
5.52
Outer Diameter (mm)
—
85.34
Inner Diameter (mm)
—
47.24
Micron Rating
3
4
Media Type
MICROGLASS
Dualglass
Media Description
—
G8 High-performance glass fiber media
Seal Material
—
Buna-N
Collapse (PSID)
3045
3000
Beta Ratio
200
4000
Beta Value
3
—
Flow Direction
OUTSIDE-IN
—
Min Temp (°F)
-13
—
Max Temp (°F)
250
—
Series
—
HP501L
Values matchValues differ—Data not available
About This Comparison
This page compares Parker PR2857 and Hy-Pro HP501L5-3M using verified manufacturer specifications from the VerifiedFilters database. A cross-reference record exists between these parts, sourced from hypro. Specifications shown are traced to manufacturer documentation. Always verify dimensional and performance compatibility before substituting filters in critical applications.