VFVerifiedFilters

HPGN181SL40-25MB vs INL-S-1813-A-CC25

Source: hypro cross-referenceVerified
Manufacturer
Hy-Pro
Indufil
Outer Diameter (in)
6.245
6.245
Inner Diameter (in)
4.25
4.25
Length (in)
40
40
Outer Diameter (mm)
158.62
Inner Diameter (mm)
158.5
Micron Rating
22
25
Media Type
Dualglass
Cellulose Composite
Media Description
G8 High-performance glass fiber media
Seal Material
Nitrile (Buna-N)
Nitrile (Buna-N)
Collapse (PSID)
400
Beta Ratio
4000
2
Min Temp (°F)
-45
-13
Max Temp (°F)
225
250
Values matchValues differData not available

About This Comparison

This page compares Hy-Pro HPGN181SL40-25MB and Indufil INL-S-1813-A-CC25 using verified manufacturer specifications from the VerifiedFilters database. A cross-reference record exists between these parts, sourced from hypro. Specifications shown are traced to manufacturer documentation. Always verify dimensional and performance compatibility before substituting filters in critical applications.