HP95RNL18-25WCV vs 1300R025WHC
No cross-reference record found between these parts
Manufacturer
Hy-Pro
Hydac
Outer Diameter (in)
5.63
5.63
Inner Diameter (in)
3.783
3.783
Length (in)
18.99
19.02
Outer Diameter (mm)
143
—
Inner Diameter (mm)
96.09
—
Micron Rating
25
25
Media Type
SS Wire Mesh
Wire Screen
Media Description
Stainless steel wire mesh
—
Seal Material
Fluorocarbon (Viton)
Nitrile (Buna-N)
Collapse (PSID)
150
2175
Beta Ratio
200
200
Flow Direction
—
Return Line (Outside-In)
Min Temp (°F)
-20
-13
Max Temp (°F)
250
250
Series
HP95RNL
—
Values matchValues differ—Data not available
About This Comparison
This page compares Hy-Pro HP95RNL18-25WCV and Hydac 1300R025WHC using verified manufacturer specifications from the VerifiedFilters database. No published cross-reference was found between these parts. Specifications shown are traced to manufacturer documentation. Always verify dimensional and performance compatibility before substituting filters in critical applications.