VFVerifiedFilters

HP7L25-25AB vs 932501

Source: hypro cross-referenceVerified
Manufacturer
Hy-Pro
Parker
Outer Diameter (in)
5.646
5
Inner Diameter (in)
3.98
4.11
Length (in)
24.3
25
Outer Diameter (mm)
127
Inner Diameter (mm)
104.39
Micron Rating
22
22
Media Type
Dualglass + Water Removal
Water Removal
Media Description
G8 glass fiber with water removal scrim
Seal Material
Nitrile (Buna-N)
Buna-N
Collapse (PSID)
150
50
Max Pressure (PSI)
150
Beta Ratio
4000
Min Temp (°F)
-45
-40
Max Temp (°F)
225
225
Series
RF7
Values matchValues differData not available

About This Comparison

This page compares Hy-Pro HP7L25-25AB and Parker 932501 using verified manufacturer specifications from the VerifiedFilters database. A cross-reference record exists between these parts, sourced from hypro. Specifications shown are traced to manufacturer documentation. Always verify dimensional and performance compatibility before substituting filters in critical applications.